How To Calibrate for IT8

The first step to calibration is getting a scan of your IT8 card. If you have gone through the Software part of the guide,you should be able to use Canon, Epson, or Vuescan scanning software to get a RAW scan of your card. 400-600DPI are recommended as the calibration software sometimes has issues with high resolution scans at 800DPI or higher. Crop around the card so there’s no white space. If you crop into the card a bit it’s okay as long as it’s within the initial grey border.

The biggest key to this is to scan your IT8 target in exactly the same way you plan to scan your boxes/manuals etc. So if you’re planning on scanning 24-bit in Epson Scan, you’ll need to scan your IT8 target the exact same way. If you’re planning on doing 48-bit sometimes as well then you’ll need to scan and calibrate a separate file for that. It’s really up to how you want to do it. For most users just one calibration file will be all that’s needed because you’ll likely always use the same settings and software when scanning.

Your scan should look similar to this image:

r181224.jpg

Now that you a RAW Scan you need to run it through calibration software and our recommendations will differed depending on your operating system but they all use the same calibration software underneath called ArgyII.